In short
The first essential indicator of Principle 6 in the BRSR asks for total energy consumption in joules or multiples, split into renewable sources (electricity A, fuel B, other C) and non-renewable sources (electricity D, fuel E, other F), the total, and energy intensity per rupee of turnover, per rupee adjusted for purchasing power parity, and per unit of physical output — for the current and the previous financial year, with a note on any independent assessment or assurance.
- Who reports it
- Every listed entity that files a BRSR; the top companies under BRSR Core with assessment or assurance
- Units
- Joules or multiples — usually GJ
- Split
- Renewable (A, B, C) and non-renewable (D, E, F)
- Intensities
- Per rupee of turnover, per rupee adjusted for PPP, per unit of physical output
- Filed
- In the annual report and in XBRL with NSE and BSE
The form, field by field
Each field with an illustrative filled example and a note on what to enter. Use Blank form to try it yourself.
SEBI's BRSR format, as revised with BRSR Core; filed in the annual report and in XBRL.
BRSR Section C, Principle 6, essential indicator 1 — Details of total energy consumption (in joules or multiples) and energy intensity
From renewable sources
Energy from renewable sources: electricity (A), fuel (B), other sources (C)
| Parameter | FY 2025-26 (current) | FY 2024-25 (previous) |
|---|---|---|
| Total electricity consumption (A) | 20,160 GJ | 14,400 GJ |
| Total fuel consumption (B) | 0 | 0 |
| Energy consumption through other sources (C) | 0 | 0 |
| Total energy consumed from renewable sources (A+B+C) | 20,160 GJ | 14,400 GJ |
Renewable electricity bought or generated, in GJ: wheeled renewable power, green tariff and on-site renewables.
Watch out: Counting grid power as renewable because the grid contains some.
From non-renewable sources
Energy from non-renewable sources: electricity (D), fuel (E), other sources (F)
| Parameter | FY 2025-26 (current) | FY 2024-25 (previous) |
|---|---|---|
| Total electricity consumption (D) | 66,240 GJ | 70,200 GJ |
| Total fuel consumption (E) — diesel 14,760 GJ; natural gas 69,745 GJ | 84,505 GJ | 87,900 GJ |
| Energy consumption through other sources (F) | 0 | 0 |
| Total energy consumed from non-renewable sources (D+E+F) | 1,50,745 GJ | 1,58,100 GJ |
Grid power and wheeled non-renewable power in D; every fuel, converted with its net calorific value, in E. Electricity from a captive generator is not added — its fuel is already in E.
Watch out: Adding a captive generator's electricity on top of its diesel: the same energy counted twice.
Totals and intensity
Total energy consumed, and the intensity ratios
| Parameter | FY 2025-26 (current) | FY 2024-25 (previous) |
|---|---|---|
| Total energy consumed (A+B+C+D+E+F) | 1,70,905 GJ | 1,72,500 GJ |
| Energy intensity per rupee of turnover | 0.0000104 GJ per ₹ (104.2 GJ per ₹ crore) | 0.0000113 GJ per ₹ (113.5 GJ per ₹ crore) |
| Energy intensity per rupee of turnover adjusted for PPP | 233 GJ per million PPP dollars | 250 GJ per million PPP dollars |
| Energy intensity in terms of physical output | 0.695 GJ per tonne | 0.747 GJ per tonne |
Revenue from operations only — not other income. For PPP, divide revenue by the year's PPP conversion factor (₹22.4 per international dollar in the example).
Watch out: A previous-year column that does not match last year's filing, without a restatement note.
Note: whether an independent assessment, evaluation or assurance was carried out by an external agency, and its name
Yes — reasonable assurance under BRSR Core; the provider named in Section A
The same provider and type as Section A items 14 and 15.
Mistakes to avoid
- Energy from renewable sources: electricity (A), fuel (B), other sources (C): Counting grid power as renewable because the grid contains some.
- Energy from non-renewable sources: electricity (D), fuel (E), other sources (F): Adding a captive generator's electricity on top of its diesel: the same energy counted twice.
- Total energy consumed, and the intensity ratios: A previous-year column that does not match last year's filing, without a restatement note.
Questions about BRSR energy table
How do I convert electricity to joules for the BRSR?
1 kWh = 3.6 MJ, so 1 MWh = 3.6 GJ. Multiply the units on the bills by 3.6 to get MJ, or MWh by 3.6 to get GJ.
Is electricity from a diesel generator counted?
Not again. The diesel burnt is counted under fuel (E); adding the generator's electricity too would count the same energy twice.
What turnover is used for energy intensity?
Revenue from operations, not other income. For the PPP-adjusted intensity, divide revenue by the year's PPP conversion factor first.
What counts as renewable electricity?
Electricity bought or generated from renewable sources with evidence: on-site solar, wheeled renewable power, a green tariff. Grid power is not counted as renewable because the grid contains some.
Do the previous-year figures have to match last year's BRSR?
Yes, unless you restate them — and a restatement needs a note explaining why.
Learn it in depth — free
Principle 6: energy, water, emissions and waste — lesson 7 of BRSR and BRSR Core: the complete practitioner course, with exercises, model answers and a certificate when you pass the exam.
Sources
- Master Circular for compliance with the SEBI (LODR) Regulations, 2015 — Chapter IV-B and Annexures 16, 17 and 17A — SEBI (copy published by NSDL). 30 January 2026; checked November 2026
- Industry Standards on Reporting of BRSR Core — Industry Standards Forum (ASSOCHAM, CII, FICCI), published by NSE. December 2024; checked November 2026
- Guidance note for the Business Responsibility and Sustainability Report (Annexure II to the circular of 10 May 2021) — SEBI. 10 May 2021; checked November 2026
Checked November 2026. Rules and forms change: check the current version with the authority before you file.