Skip to content

BRSR and BRSR Core · Lesson 7 of 18 · Module 2 — The format, section by section

Principle 6: energy, water, emissions and waste

30 minFacts checked November 2026

In this lesson you will learn to

  • Prepare each table of Principle 6 — energy, water withdrawal and discharge, air emissions, Scope 1 and 2, waste — with the right units
  • Convert electricity and fuels into joules and split renewable from non-renewable
  • Calculate water consumption, and estimate it where there are no meters
  • Classify waste into the BRSR's eight categories and its recovery and disposal routes

Principle 6 holds the environmental figures — energy, water, air emissions, greenhouse gases and waste — and it is where most BRSR Core assurance effort goes. Every number here should trace to a meter, a bill, a manifest or a calculation sheet.

The thirteen essential indicators

#IndicatorUnit and detail
1Energy consumedJoules or multiples; electricity, fuel and other sources, each split into renewable and non-renewable; intensity per rupee of turnover (PPP-adjusted) and optionally per unit of output — BRSR Core
2Perform, Achieve and Trade (PAT) schemeWhether any site is a designated consumer under the Bureau of Energy Efficiency's PAT scheme, and whether targets were met
3Water withdrawal and consumptionKilolitres; withdrawal by source — surface water, groundwater, third-party water, seawater or desalinated water, others; consumption; intensity — BRSR Core
4Water dischargeKilolitres by destination — surface water, groundwater, seawater, third parties, others — and by level of treatment — BRSR Core
5Zero liquid dischargeWhether a mechanism exists, its coverage and implementation
6Air emissions other than GHGNOx, SOx, particulate matter, persistent organic pollutants, volatile organic compounds, hazardous air pollutants, others — with units
7Scope 1 and Scope 2 emissionsTonnes CO₂e; intensity — BRSR Core
8GHG reduction projectsDescription
9Waste generated, recovered and disposedMetric tonnes by category; recovery by recycling, re-use and other recovery; disposal by incineration, landfill and other; intensity — BRSR Core
10Waste management practicesIncluding the strategy to reduce hazardous and toxic chemicals
11Ecologically sensitive areasOperations in or near them, and compliance with environmental clearance conditions
12Environmental impact assessmentsThose done in the year
13Compliance with environmental lawNon-compliances, penalties and corrective action

Source: Annexure 162. Leadership indicators include water in water-stressed areas (areas the Central Ground Water Board classes as over-exploited or critical), Scope 3 emissions, biodiversity, resource efficiency initiatives, a business continuity and disaster management plan, value chain impacts and assessments, and green credits2.

Energy: everything in joules

Energy conversions: 1 kWh is 3.6 MJ and 1 MWh is 3.6 GJ; fuels are converted with their net calorific value; a worked example totals 1,70,905 GJ with 11.8% renewable
Energy in joules

The BRSR asks for energy in joules, split into renewable and non-renewable, for three source types: electricity, fuel and "other". The conversion you will use most is:

1 kWh = 3.6 MJ, so 1 MWh = 3.6 GJ, and 1,000 MWh = 3.6 TJ.

Fuels are converted with their net calorific value (energy per litre, kilogram or cubic metre), taken from a stated source — the supplier's test certificate, an accredited laboratory, or a published default such as the IPCC's — and the source must be disclosed9.

Purchased electricity is split into its components — wheeled renewable power, wheeled non-renewable power, green tariff and grid power — and each is classed as renewable or non-renewable; the same split feeds Scope 29. Electricity a company generates itself is counted once: the fuel burned in a captive generator is counted, and the electricity it produces is not added again2.

What the energy table looks like. Principle 6, essential indicator 1, as it appears in the BRSR format, filled in for the plant in the example (revenue from operations ₹1,640 crore; 2,46,000 tonnes of product). The same table is filed in the XBRL.

Form walkthrough

SEBI's BRSR format, as revised with BRSR Core; filed in the annual report and in XBRL.

BRSR Section C, Principle 6, essential indicator 1 — Details of total energy consumption (in joules or multiples) and energy intensity

From renewable sources

Energy from renewable sources: electricity (A), fuel (B), other sources (C)

ParameterFY 2025-26 (current)FY 2024-25 (previous)
Total electricity consumption (A)20,160 GJ14,400 GJ
Total fuel consumption (B)00
Energy consumption through other sources (C)00
Total energy consumed from renewable sources (A+B+C)20,160 GJ14,400 GJ

Renewable electricity bought or generated, in GJ: wheeled renewable power, green tariff and on-site renewables.

Watch out: Counting grid power as renewable because the grid contains some.

From non-renewable sources

Energy from non-renewable sources: electricity (D), fuel (E), other sources (F)

ParameterFY 2025-26 (current)FY 2024-25 (previous)
Total electricity consumption (D)66,240 GJ70,200 GJ
Total fuel consumption (E) — diesel 14,760 GJ; natural gas 69,745 GJ84,505 GJ87,900 GJ
Energy consumption through other sources (F)00
Total energy consumed from non-renewable sources (D+E+F)1,50,745 GJ1,58,100 GJ

Grid power and wheeled non-renewable power in D; every fuel, converted with its net calorific value, in E. Electricity from a captive generator is not added — its fuel is already in E.

Watch out: Adding a captive generator's electricity on top of its diesel: the same energy counted twice.

Totals and intensity

Total energy consumed, and the intensity ratios

ParameterFY 2025-26 (current)FY 2024-25 (previous)
Total energy consumed (A+B+C+D+E+F)1,70,905 GJ1,72,500 GJ
Energy intensity per rupee of turnover0.0000104 GJ per ₹ (104.2 GJ per ₹ crore)0.0000113 GJ per ₹ (113.5 GJ per ₹ crore)
Energy intensity per rupee of turnover adjusted for PPP233 GJ per million PPP dollars250 GJ per million PPP dollars
Energy intensity in terms of physical output0.695 GJ per tonne0.747 GJ per tonne

Revenue from operations only — not other income. For PPP, divide revenue by the year's PPP conversion factor (₹22.4 per international dollar in the example).

Watch out: A previous-year column that does not match last year's filing, without a restatement note.

Note: whether an independent assessment, evaluation or assurance was carried out by an external agency, and its name

Yes — reasonable assurance under BRSR Core; the provider named in Section A

The same provider and type as Section A items 14 and 15.

Rows as in the BRSR format in SEBI's master circular2; method from the Industry Standards9. The entries are an illustrative example. Check the current form with the authority before you file. BRSR energy table: due date, penalty and questions.

Water: withdrawal, discharge and consumption

Consumption = withdrawal − discharge. BRSR Core expects these from calibrated flow meters at intake and outlet2. Where there is no meter — typically offices — the Industry Standards allow an estimate of 45 litres per head per working day for employees and workers, and the share of a shared building is allocated by floor area9.

Scope 1 and Scope 2

The BRSR follows the GHG Protocol Corporate Standard14 and asks for Scope 1 and Scope 2 in tonnes of CO₂ equivalent, covering the seven Kyoto gases2:

  • Scope 1 — direct emissions: fuel combustion in boilers, furnaces, generators and vehicles; process emissions; and fugitive emissions such as refrigerant leaks. In BRSR Core: fuel × emission factor, minus carbon captured, plus process and fugitive emissions2.
  • Scope 2 — purchased electricity, heat, steam and cooling: quantity × emission factor. For grid electricity in India, the Industry Standards require the latest grid emission factor of the Central Electricity Authority (CEA)9. CEA's CO2 Baseline Database version 22 gives a weighted average of 0.710 tCO₂/MWh for FY 2024-2511.

Emission factors must come from a recognised source — an accredited laboratory, the IPCC, IEA, UK DEFRA, US EPA or a country-specific source — and the source must be stated9. The greenhouse gas accounting course covers the methods in depth.

Waste: eight categories and two routes

BRSR waste categories, in metric tonnes2:

CodeCategory
APlastic waste
BE-waste
CBio-medical waste
DConstruction and demolition waste
EBattery waste
FRadioactive waste
GOther hazardous waste (please specify)
HOther non-hazardous waste (please specify, by composition)

For each, the company reports how much was recovered — recycled, re-used or by other recovery operations — and how much was disposed of — by incineration, landfill or other operations. Evidence is the hazardous waste manifests (Form 10 under the Hazardous and Other Wastes Rules), the recycler's or processor's certificates, and weighbridge slips; BRSR Core allows reliance on vendor certificates for waste2.

Practice

Build the energy and water tables

A plant's records for FY 2025-26:

  • Grid electricity: 18,400 MWh. Open-access wind power: 3,500 MWh. Rooftop solar generated and used on site: 2,100 MWh.
  • High-speed diesel: 4,10,000 litres. Natural gas: 18,50,000 standard cubic metres.
  • Water: borewell 92,000 kL, municipal supply 60,000 kL. Treated effluent discharged to the municipal sewer: 41,000 kL (after secondary treatment).

Use these illustrative factors: diesel 36 MJ per litre; natural gas 37.7 MJ per standard cubic metre.

  1. Total energy in GJ, and the renewable share.
  2. Water withdrawal by source, discharge, and consumption.
Show the model answer

Energy

  • Electricity: (18,400 + 3,500 + 2,100) MWh × 3.6 = 86,400 GJ. Renewable: 5,600 MWh × 3.6 = 20,160 GJ. Non-renewable: 18,400 × 3.6 = 66,240 GJ.
  • Diesel: 4,10,000 × 0.036 GJ = 14,760 GJ (non-renewable fuel).
  • Natural gas: 18,50,000 × 0.0377 GJ = 69,745 GJ (non-renewable fuel).
  • Total = 1,70,905 GJ (170.9 TJ). Renewable share = 20,160 ÷ 1,70,905 = 11.8%.

Water

  • Withdrawal: groundwater 92,000 kL; third-party water 60,000 kL; total 1,52,000 kL.
  • Discharge: to third parties (municipal sewer), secondary treatment: 41,000 kL.
  • Consumption = 1,52,000 − 41,000 = 1,11,000 kL.

Note the borewell: if the plant is in a block the Central Ground Water Board classes as over-exploited or critical, it also belongs in the leadership indicator on water-stressed areas.

Check your understanding

Choose an answer to see if you are right.

How is water consumption defined in the BRSR?

Show the answer

B. Total water withdrawal minus total water discharge The BRSR defines consumption as withdrawal minus discharge.

What should a company do with grid electricity when calculating Scope 2 in India, according to the Industry Standards?

Show the answer

B. Use the latest grid emission factor of the Central Electricity Authority The Industry Standards require the latest CEA grid emission factor for Scope 2 in India.

Sources for this lesson

  1. Master Circular for compliance with the SEBI (LODR) Regulations, 2015 — Chapter IV-B and Annexures 16, 17 and 17A — SEBI (copy published by NSDL). 30 January 2026; checked November 2026
  2. Industry Standards on Reporting of BRSR Core — Industry Standards Forum (ASSOCHAM, CII, FICCI), published by NSE. December 2024; checked November 2026
  3. CO2 Baseline Database for the Indian Power Sector, User Guide, Version 22.0 — Central Electricity Authority. August 2026; checked November 2026
  4. GHG Protocol Corporate Accounting and Reporting Standard, Revised Edition — WRI and WBCSD. 2004; checked November 2026

Completing every lesson opens the exam and the certificate. Sign in with your e-mail to record your progress — no password and no account.

More: BRSR practice questions · notes (PDF) · ESG glossary

Report it with the evidence behind every figure

ESGTrack prepares BRSR, CSRD and ISSB reports from approved data, with an audit trail an assurer can test.