In this lesson you will learn to
- Name the seven greenhouse gases an inventory must cover
- Convert any gas to CO₂e with the right GWP
- Choose and disclose a GWP set (AR4, AR5 or AR6) and use fossil or non-fossil methane correctly
- Calculate the GWP of a refrigerant blend
An inventory counts seven gases, and converts each into carbon dioxide equivalent (CO₂e) with its global warming potential (GWP) — how much warming one tonne causes over 100 years compared with one tonne of CO₂.
The seven gases
The GHG Protocol requires4:
- carbon dioxide (CO₂) — burning fuels, cement and other processes;
- methane (CH₄) — waste and waste water, coal mining, gas leaks, livestock and rice;
- nitrous oxide (N₂O) — fertilisers, some chemical processes, combustion;
- hydrofluorocarbons (HFCs) — refrigerants in air-conditioning and chillers;
- perfluorocarbons (PFCs) — aluminium smelting, electronics;
- sulphur hexafluoride (SF₆) — insulation in high-voltage switchgear;
- nitrogen trifluoride (NF₃) — electronics manufacturing; added in 2013.
GWPs: which values
The IPCC revises GWPs in each assessment report (AR). The GHG Protocol's 2024 table sets them side by side, and recommends the latest, AR68:
| Gas | AR4 | AR5 | AR6 |
|---|---|---|---|
| CO₂ | 1 | 1 | 1 |
| CH₄, non-fossil | 25 | 28 | 27.0 |
| CH₄, fossil | — | 30 | 29.8 |
| N₂O | 298 | 265 | 273 |
| SF₆ | 22,800 | 23,500 | 24,300 |
| NF₃ | 17,200 | 16,100 | 17,400 |
| HFC-32 | 675 | 677 | 771 |
| HFC-125 | 3,500 | 3,170 | 3,740 |
| HFC-134a | 1,430 | 1,300 | 1,530 |
| HFC-143a | 4,470 | 4,800 | 5,810 |
| PFC-14 (CF₄) | 7,390 | 6,630 | 7,380 |
Rules for using them:
- Pick one set and disclose it. Use the same set for every year you compare; if you change sets, recalculate the base year.
- Fossil or non-fossil methane. Use the fossil value for fugitive emissions from fossil sources (gas leaks, coal mines) and for processes using fossil carbon; the non-fossil value for combustion and other sources8.
- Check what your framework requires. IFRS S2 asks for the latest IPCC values at the reporting date7; some programmes prescribe a set.
CO₂e = tonnes of gas × GWP.
Refrigerant blends
Many refrigerants are blends; their GWP is the mass-weighted average of their components. R-410A, common in air-conditioners, is 50% HFC-32 and 50% HFC-125.
Practice
Convert to CO₂e
Using AR6 values, convert:
- 4 tonnes of N₂O from a nitric acid process.
- 2.5 kg of SF₆ leaked from switchgear.
- 120 kg of R-32 (pure HFC-32) added to chillers.
- 3 tonnes of methane leaked from the company's natural gas pipelines.
Show the model answer
- 4 × 273 = 1,092 tCO₂e.
- 2.5 kg × 24,300 = 60,750 kg = 60.75 tCO₂e.
- 120 kg × 771 = 92,520 kg = 92.5 tCO₂e.
- Fossil methane (a fugitive leak from a fossil source): 3 × 29.8 = 89.4 tCO₂e.
Small masses of high-GWP gases matter: 2.5 kg of SF₆ outweighs 22,000 litres of diesel.
Check your understanding
Choose an answer to see if you are right.
Sources for this lesson
- Required Greenhouse Gases in Inventories: Accounting and Reporting Standard Amendment — WRI and WBCSD. February 2013; checked November 2026
- IFRS S2: Climate-related Disclosures — IFRS Foundation. June 2023, as amended December 2025; checked November 2026
- Global Warming Potential Values (August 2024) — GHG Protocol. August 2024; checked November 2026
Completing every lesson opens the exam and the certificate. Sign in with your e-mail to record your progress — no password and no account.
More: GHG Accounting practice questions · notes (PDF) · ESG glossary